{"product_id":"gamewell-fci-amm-2f-velociti-series-addressable-monitor-module","title":"Gamewell-FCI AMM-2F Velociti Series Addressable Monitor Module","description":"\u003cp\u003e\u003cstrong\u003eAMM-2F\u003c\/strong\u003e is a Gamewell-FCI Velociti Series addressable monitor module with one Style B (Class B) initiating device circuit supervised by a 47K ohm end-of-line resistor. It gives an address on the signaling line circuit (SLC) of a Gamewell-FCI addressable fire alarm control panel to any device or group of devices with normally open dry contacts, such as manual stations, waterflow switches or tamper switches. Its compact size allows it to be installed inside manual stations or in the mounting boxes of initiating devices.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCircuit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOne initiating device circuit, Style B, Class B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNormally open (N.O.) dry contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnd-of-line resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e47K ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. IDC line resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupervisory current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.000375 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAlarm current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.00060 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32°F to 120°F (0°C to 49°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10% to 93%, noncondensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.3 in L x 2.5 in W x 0.5 in D (3.3 x 6.4 x 1.3 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eListings and approvals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL S1949; FM 3023594; MEA FDNY 227-03-E Vol. IV; CSFM 7300-1703:0102\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eCompatibility and installation notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstalls on the SLC of Gamewell-FCI addressable series fire alarm control panels.\u003c\/li\u003e\n\u003cli\u003eCan be programmed as a manual station, heat detector, plenum detector, waterflow switch, tamper switch, N.O. contact, smoke detector, projected beam detector, sub loop or remote zone, among other device types.\u003c\/li\u003e\n\u003cli\u003eCan also serve as a remote system silence, system reset, system acknowledge or drill switch input.\u003c\/li\u003e\n\u003cli\u003eThe 40 ohm line resistance allowance supports linear heat detection devices on the initiating circuit.\u003c\/li\u003e\n\u003cli\u003eInstall a 47K ohm end-of-line resistor on the initiating device circuit.\u003c\/li\u003e\n\u003cli\u003eRefer to the Gamewell-FCI panel installation manual for wiring and device capacity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRelated models\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAMM-4F: Gamewell-FCI addressable monitor module (data sheet 9020-0624)\u003c\/li\u003e\n\u003cli\u003eAMM-2IF: Gamewell-FCI addressable monitor module (data sheet 9020-0629)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/prod-edam.honeywell.com\/content\/dam\/honeywell-edam\/hbt\/en-us\/documents\/literature-and-specs\/datasheets\/9020-0626.pdf\"\u003eGamewell-FCI data sheet 9020-0626 (AMM-2F)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/buildings.honeywell.com\/us\/en\/products\/by-category\/fire-life-safety\/i-o-modules\/monitor-modules\/gamewell-addressable-monitor-module\"\u003eHoneywell product page: Gamewell Addressable Monitor Module\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eSpecifications from Gamewell-FCI data sheet 9020-0626, revision F (11\/17). Manufacturer specifications are subject to change.\u003c\/em\u003e\u003c\/p\u003e","brand":"Gamewell-FCI","offers":[{"title":"Default Title","offer_id":53970011717925,"sku":"AMM-2F","price":60.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0785\/7648\/4645\/files\/AMM-2F.webp?v=1791304512","url":"https:\/\/fastalarm.com\/products\/gamewell-fci-amm-2f-velociti-series-addressable-monitor-module","provider":"FastAlarm.com","version":"1.0","type":"link"}