{"product_id":"edwards-siga-cod-signature-series-intelligent-carbon-monoxide-detector","title":"Edwards SIGA-COD Signature Series Intelligent Carbon Monoxide Detector","description":"\u003cp\u003e\u003cstrong\u003eSIGA-COD\u003c\/strong\u003e is an Edwards Signature Series intelligent carbon monoxide detector with an electrochemical CO sensor. It is compatible only with the Signature Loop Controller. The detector's microprocessor analyzes sensor readings over time to decide when to initiate a CO alarm, runs continuous self-diagnostics, and signals a trouble condition to the panel when the CO cell reaches end of life. It plugs into a separately ordered Signature Series detector base.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensing technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElectrochemical carbon monoxide sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15.20 to 19.95 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNormal operating current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e51 µA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAlarm current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e68 µA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCO alarm levels (per UL 2034, CAN\/CSA 6.19)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 ppm: 60-240 min; 150 ppm: 10-50 min; 400 ppm: 4-15 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCO false alarm levels (per UL 2034, CAN\/CSA 6.19)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 ppm: 30 days; 70 ppm: 60 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensor life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 years from date of manufacture or panel end-of-life indication, whichever comes first (EST3\/EST3X panels use 6-year timing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating environment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32°F to 120°F (0°C to 49°C), 0-90% RH noncondensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-4°F to 140°F (-20°C to 60°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 to 35 Hz, amplitude 0.01 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHigh-impact engineering polymer, white\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStatus LED\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBicolor (green\/red)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible detector testers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTestifire 1000, Testifire 2000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAgency listing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL 2075; evaluated to the CO alarm sensitivity limits of UL 2034\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShipping weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.4 lb (0.16 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eCompatibility and installation notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCompatible only with the Edwards Signature Loop Controller; feature support depends on the control panel.\u003c\/li\u003e\n\u003cli\u003eCompatible bases: SIGA-SB, SIGA-SB4, SIGA-RB, SIGA-RB4, SIGA-IB, SIGA-IB4, SIGA-AB4GT and SIGA-AB4G-LF. SIGA-LED remote LED works with SIGA-SB\/SB4 only.\u003c\/li\u003e\n\u003cli\u003eFor a CO (TC4) tone pattern on SIGA-AB4GT or SIGA-AB4G-LF sounder bases, a SIGA-TCDR Temporal Pattern Generator is required.\u003c\/li\u003e\n\u003cli\u003eBases mount to North American 1-gang boxes, 3-1\/2 in or 4 in octagon boxes 1-1\/2 in (38 mm) deep; 4 in bases also fit 4 in square boxes.\u003c\/li\u003e\n\u003cli\u003eBases accept 18 to 12 AWG wire; 16 and 18 AWG are preferred.\u003c\/li\u003e\n\u003cli\u003eAt end of sensor life the panel shows a trouble that remains until the detector is replaced. Plan maintenance per NFPA 72, NFPA 720 and the AHJ.\u003c\/li\u003e\n\u003cli\u003eThe manufacturer notes that people with special medical conditions may need devices that alarm below 30 ppm.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRelated models\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSIGA-COD-CA: Canadian market version, ULC listed to CAN\/CSA 6.19\u003c\/li\u003e\n\u003cli\u003eSIGA-OSHCD: Signature Series smoke, heat and CO detector\u003c\/li\u003e\n\u003cli\u003eSIGA-HRD: Signature Series fixed temperature\/rate-of-rise heat detector\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/myeddie.edwardsfiresafety.com\/PublicMedia\/Catalog%20Sheets\/E85001-0648%20--%20Intelligent%20CO%20Detector.pdf\"\u003eEdwards data sheet E85001-0648, Intelligent CO Detector\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eSpecifications from Edwards data sheet E85001-0648, Issue 1.3. Manufacturer specifications are subject to change.\u003c\/em\u003e\u003c\/p\u003e","brand":"Edwards","offers":[{"title":"Default Title","offer_id":53970012307749,"sku":"SIGA-COD","price":115.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0785\/7648\/4645\/files\/SIGA-COD.jpg?v=1791304539","url":"https:\/\/fastalarm.com\/products\/edwards-siga-cod-signature-series-intelligent-carbon-monoxide-detector","provider":"FastAlarm.com","version":"1.0","type":"link"}